Caja de Navegación Local |
||
|
Each one of the HRLM photographs below has a TEM couterpart. Can you match them and make a diagnosis? |
Cada una de las fotos por MOAR aquí abajo tiene su contraparte por MET. Puede parearlas y hacer un diagnóstico? . |
||
|
|
|
![]() |
![]() |
|
Meninges HRLM / MOAR 1 |
Liver HRLM / MOAR 2 |
Kidney HRLM / MOAR 3 |
Pancreas HRLM / MOAR 4 |
![]() |
![]() |
|
![]() |
|
TEM / MET 1 |
TEM / MET 2 |
TEM / MET 3 |
TEM / MET 4 |
|
For more detail click on the HRLM photographs. |
Para mas detalle pulse sobre las fotos para MOAR. |
||
|
Introduction:
Welcome to our
page High Resolution Light Microscopy (HRLM) - Transmission
Electron Microscopy (TEM). Sub cellular structures in
paraffin sections are difficult to visualize in the light
microscope due to limitations of the method itself. However,
this instrument is capable to resolve structures of 0.2um.
This is the size of a mitochondrion or a neuro endocrine
granule. The difficulty of visualizing these structures in
the light microscope, is not a problem of the microscope, it
is a problem of inadequate processing. The use of electron
microscopy histotechnology (epoxy histotechnology) preserves
tissues with little shrinkage, little distortion and little
loss of substance, permitting the visualization of sub
cellular diagnostic structures in the light microscope,
without the use of special stains. In surgical pathology
this permits the full utilization of the resolving power of
the light microscope allowing more accurate and faster
diagnosis. This we call
High
Resolution Light Microscopy or
HRLM. |
Introducción:
Bienvenidos a nuestra página Microscopía
Optica de Alta Resolución (MOAR) - Microscopía Electrónica de
Transmisión (MET). Estructuras sub celulares son difíciles de ver en
los cortes de parafina debido a limitaciones del método mismo. Sin
embargo, el microscopio óptico tiene una capacidad para resolver
hasta 0.2um. Este es el tamaño de una mitocondria o de un gránulo de
neuro secreción. La dificultad para ver éstas estructuras en el
microscopio de luz no es debido al microscopio óptico, es debido al
procesamiento inadecuado de los tejidos. La aplicación de la
histotecnología usada para microscopía electrónica (histotecnología
por epoxies) preserva los tejidos sin encogerlos, sin distorsión y
sin pérdida de substancia, permitiendo la visualización de lesiones
diagnósticas sub celulares sin necesidad de coloraciones especiales.
Esto permite en patología quirúrgica, la utilización plena del poder
de resolución del microscopio de luz, produciendo diagnósticos más
certeros y más rápidos. El método lo llamamos
Microscopía
Optica de Alta Resolución o
MOAR. |
||
|
Methods:
The biopsies were fixed
in paraformaldehyde, post fixed in osmic acid and embedded
in epoxy Spurr. The histologic sections 1-2um thick, were
stained with Toluidin blue and Basic Fuchsin (TB-BF). With
this method the full resolving power of the light microscope
can be utilized (0.2um). This we call High Resolution Light
Microscopy (HRLM). This is not possible with paraffin
sections. |
Métodos:
Las biopsias fueron
fijadas en paraformaldehido, post fijadas en ácido
ósmico e incluidas en epoxy Spurr. Los cortes
histológicos son de 1-2um de espesor, coloreadas con
azul de toluidina y fuchsina básica (AT-FB). Con este
método se puede utilizar en una forma óptima
el poder de resolución del microscopio de luz
(0.2um). Esto no es posible con cortes de parafina. |
||
|
Uses and limitations for HRLM: HRLM is very useful in Anatomic Pathology where the majority of the diagnosis are made by the recognition of sub cellular structures (kidney, liver, nervous system, endocrine, microorganisms, others). We have replaced paraffin sections with epoxy sections for HRLM in all our renal biopsies with great success. However HRLM sections in diagnostic pathology are difficult to interpret because the diagnostic lesions are difficult to recognize since they have unusual detail and different colors and also because the lack of experience of most Pathologists with sections rich in sub cellular detail not present in the paraffin sections. As far as different colors are concerned, I do agree that colors are different in the sections for HRLM. However, a pathologist that has the expertise to recognize a lesion, probably will recognize it whether is blue, yellow or red. In the same way that an expert in automobiles will recognize different brands of cars regardless of the color. Therefore, the inability to recognize diagnostic features in the sections for HRLM, is not because the different colors, it probably because of ignorance. Something similar happens with the rich cellular detail seen in the HRLM sections. The experienced pathologists knows of the existence of all the detail in the diagnostic lesions however, it is not used to see them in a single slide because in the paraffin sections these are difficult to see, need special methods, or they are not seen at all. However, for this experienced pathologist, it will take little additional experience to be able to recognize these features. Epoxy sections for HRLM do not reveal new lesions, new diagnostic features. All what they do is making them visible in a single section, taking full advantage of the resolving power of the light microscope (0.2 um) which is not possible with the paraffin sections. Perhaps the biggest limitation for the use of HRLM is the tradition of more than a century of the paraffin sections and the lack of references and training in HRLM. The need to introduce a new technology in an established Laboratory is also difficult. |
Usos y limitaciones en MOAR: MOAR es muy útil en Anatomía Patológica donde la mayoría de los diagnósticos se hacen por el reconocimiento de estructuras sub celulares (riñón, hígado sistema nervioso, endocrino, microorganimos otros). Nosotros hemos reemplazado los cortes de parafina por cortes de epoxy para MOAR para todas nuestras biopsias renales, con mucho éxito. Sin embargo, se debe tener en cuenta que los cortes para MOAR son difíciles de interpretar por que las lesiones diagnosticas tienen diferentes colores y también por la falta de experiencia de la mayoría de los Patólogos que no están acostumbrados a ver el detalle sub celular que no se ve en los cortes de parafina. Estoy de acuerdo que los cortes para MOAR presentan colores diferentes y detalle extraordinario, sin embargo, un Patólogo experto en reconocer lesiones diagnosticas, las reconocerá así estén en azul, amarillo o rojo. De la misma manera que un experto en automóviles reconocerá las diferentes marcas de carros aun que tengan diferentes colores. Por lo tanto el no reconocer una lesión por que es de otro color es probablemente no porque tiene diferente color sino por ignorancia. Algo similar ocurre con el detalle celular que se ve en los cortes para MOAR. El Patólogo experimentado sabe de la existencia de los detalles en toda lesión diagnostica, pero no esta acostumbrado a verlos en un solo corte, por que en los cortes de parafina son difíciles de ver, necesitan métodos especiales o no se ven del todo. Sin embargo, para este Patólogo experimentado, tomara muy poca experiencia adicional para reconocer todos estos detalles. En los cortes para MOAR no se descubren lesiones nuevas, todo lo que se consigue es hacerlas todas visibles en un mismo corte, aprovechando de la resolución máxima del microscopio de luz (0.2um), lo que no es posible con los cortes de parafina. Quizás la imitación mas grande es la tradición de mas de un siglo de los cortes de parafina y la falta de referencias y adiestramiento con esta metodología nueva para MOAR. La necesidad de introducir una tecnología nueva en un laboratorio establecido es también dificil. |
||
|
Uses for Dx TEM: Diagnostic Transmission Electron Microscopy has a well defined place in surgical Pathology. However, its use and correct application is still not very well underastood or widespread. The Society for Ultrastructural Pathology suggests the following indications for the use of DX TEM. IN TUMOR
PATHOLOGY.
Specific Indications:
|
Usos de MET Dx: La microscopía Electrónica de Transmision para Diagnóstico tiene un lugar bien definido en Patología Quirúrgica. Sinembargo su uso correcto y su aplicacion parecen no ser aun bien entendidos o generalizados. La Sociedad de Patologia Ultraestructural, sugiere las indicaciones siguientes para el uso de MET DX. EN PATOLOGIA
TUMORAL.
Indicaciones específicas:
Subclasificacion de los sarcomas. |
||
|
INDICATIONS IN NON-NEOPLASTIC DISEASES:
Identification of foreign material in tissues. |
INDICACIONES EN ENFERMEDADES NO NEOPLASICAS:
Identificación de material extraño en tejidos. |
||
|
We believe that TEM should be used when the diagnostic features of the problem case are structures and are smaller that the resolving capabilities (power) of the Light Microscope (LM) (0.2 um). With paraffin sections this power is reduced approximately to 2.0 um. |
Nosotros creemos que MET se debe usar cuando la facción diagnóstica es una estructura y es mas pequeña que el poder de resolución del microscopio de luz (ML) (0.2 um). En los cortes de parafina este poder se reduce aproximadamente a 2.0 um. |
||
|
|
||
|
Each level of biological organization has specific characteristics that may be studied by specialized methods. These methods may have little or no applications at other levels (Dr. Ruy Perez-Tamayo).
|
Cada nivel de organización biológica tiene características específicas que pueden estudiarse por métodos especializados. Estos métodos pueden tener poca o ninguna aplicación a otros niveles (Dr. Ruy Perez Tamayo)
|
||
| REFERENCES | REFERENCIAS | ||